Hotspots and fire risk
Loose, high-resistance power connections heat up under load cycling. Butlr watches the full power path continuously, designed to catch electrical faults before they escalate.
See every risk to your compute, live, from one screen. Butlr brings continuous thermal sensing, live 360 video, and server telemetry into one view, so your team catches what takes GPUs offline before it does.

Server management chips report what happens inside the box. The power path, the coolant loop, and the people moving through the hall sit outside it. That is where outages start, and where Butlr looks.
Already reported by the server's management chip. Butlr brings it into the same view as everything around it.
Unwatched between annual inspections and walkdowns. Butlr measures it continuously, from the white space to inside the rack.
Loose, high-resistance power connections heat up under load cycling. Butlr watches the full power path continuously, designed to catch electrical faults before they escalate.
Leak detection for liquid-cooled systems is in development on the same alerting platform, extending coverage from the power path to the coolant loop.
Training jobs spread unevenly across racks create hot racks and wasted capacity. Butlr shows server telemetry next to the thermal map, so heat and load are read together.
A single rack of GPUs can be worth millions, on site and in transit. Butlr pairs anonymous presence sensing with optional live 360 video across the hall.
Explore thermal views and BMC server telemetry together in the Butlr dashboard.
Manage the facility remotely with a view that is better than walking the floor. Every layer is live, and every layer sits in one dashboard.

Every mechanical connection in the high-current path can loosen and heat as loads cycle. Rack PDUs report current, not the temperature at each joint, and nothing reports the tap-off above the rack.


01 / 05
Switchgear and breaker connections
The most upstream connections carry the most load, and a fault here takes down everything below it. Battery-powered sensors watch breaker connections inside the cabinet continuously, where inspections used to happen through a small window.








Continuous monitoring reduces the risk insurers and lenders price in, and it pulls the commissioning schedule forward. The layer pays for itself fast.
Figures are modelled estimates from the Butlr data center ROI model, not quotations or forecasts of realized results.
The line-item model is available under NDA.
Butlr thermal sensors capture heat, never images. Live video is an optional add-on you turn on where you want it.
Wireless for the white space, wired PoE in the rack on the management network. No hall shutdown.
Per-zone thresholds, routed to the systems your team already watches.
API-first, with integrations into building and facility platforms.
Walk through the thermal digital twin of a running AI module, updating live, and see how heat, water, load, and access come together in one view.